Allen-Bradley 100S-C97KD14C

View Cut Sheet PDF

 

\

Mechanically linked N.C. auxiliary contacts

Front-mounted auxiliary contacts

− Gold bifurcated

− Permanently fixed

− Protective cover to prevent manual operation

− Red contact housing foreasy identification

− Incorporates IEC 60947-5-1 “Mechanically Linked” symbol

AC and DC operating coils

SUVA Third-Party certification

Bulletin 100S-C/104S-C safety contactors provide mechanically linked

positively guided contacts, required in feedback circuits of modern

safety applications. The mechanically linked N.C. auxiliary contacts will

not change state when a power pole welds. In addition, the gold-plated

bifurcated auxiliary contacts are ideally suited for low-energy

applications or feedback control circuits with multiple series-connected

N.C. auxiliary contacts.

Your order must include: cat. no. of the contactor specified with coil

voltage code and, if required, cat. no. of any accessories and/or

replacement coils.

Standards Compliance

Certifications

SUVA Third-Party Certified

CE Marked

cULus Listed (File No. E3125;

Guide NLDX, NLDX7)

Product Selection

3-Pole AC- and DC-Operated Contactors

Coil voltage code and terminal positionsee page 2-137

Table of Contents

Product Selection …… this page

Accessories……………… 2-142

Approximate

Dimensions………………. 2-195

Bulletin 100S-C/104S-C — IEC Safety Contactors

Cat. No.

100S-C0905C

Line Side

Cat. No.

100S-C09U05C

Load Side

Overview/Product Selection

13

12

11

10

9

8

7

6

5

4

3

2

1

0

2-134

Bulletin 100S-C/104S-C

IEC Safety Contactors

Ie [A]

Ratings for Switching AC Motors — AC-2, AC-3, AC-4 Aux. Contacts

Cat. No.

3-Phase kW (50 Hz) Hp (60 Hz)

AC-3 AC-1 230V

400V/

415V 500V 690V

1-Phase 3-Phase

115V 230V 200V 230V 460V 575V N.O. N.C.

9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2

0 5 100S-C0905BC

1 4 100S-C0914BC

12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10

0 5 100S-C1205BC

1 4 100S-C1214BC

16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15

0 5 100S-C1605BC

1 4 100S-C1614BC

23 32 7.5 11 13 10 2 3 5 7-1/2 15 15

0 5 100S-C2305BC

1 4 100S-C2314BC

30 65 10 15 15 15 2 5 7-1/2 10 20 25

0 4 100S-C3004BC

1 4 100S-C3014BC

37 65 11 18.5/20 20 18.5 3 5 10 10 25 30

0 4 100S-C3704BC

1 4 100S-C3714BC

43 85 13 22 25 22 3 7-1/2 10 15 30 30

0 4 100S-C4304BC

1 4 100S-C4314BC

60 100 18.5 32 37 32 5 10 15 20 40 50

0 4 ‡ 100S-C6004BC

1 4 ‡ 100S-C6014BC

72 100 22 40 45 40 5 15 20 25 50 60

0 4 ‡ 100S-C7204BC

1 4 ‡ 100S-C7214BC

85 100 25 45 55 45 7-1/2 15 25 30 60 60

0 4 ‡ 100S-C8504BC

1 4 ‡ 100S-C8514BC

97 130 30 55 55 55 10 15 30 30 75 75

0 4 ‡ 100S-C9704BC

1 4 ‡ 100S-C9714BC

For other contact configurations and full product details, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-

C0905BC becomes Cat. No. 100S-C0905C.

‡ Bifurcated front-mount auxiliary contacts on Cat. Nos. 100S-C60…C97 conform to mirror contact performance only.

www.ab.com/catalogs     Preferred availability cat. nos. are bold.

Publication A117-CA001A-EN-P

EN50205

CSA C22.2 No. 14

UL 508

EN/IEC 60947-4

IEC 60947-4-1 Annex H — Mirror

Contacts

IEC 60947-5-1 Annex L —

Mechanically Linked Contacts

Meets the material restrictions for

European Directive

2002/95/IEC-EU-RoHS

 

\

4-Pole AC- and DC-Operated Contactors

Coil voltage code and terminal positionsee page 2-137

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Product Selection

2-135

Bulletin 100S-C/104S-C

IEC Safety Contactors

Ie [A]

Ratings for Switching AC Motors

Contact Configuration

Cat. No. ‡

AC-2, AC-3, AC-4

Hp (60 Hz)3-Phase kW (50 Hz) Main Pole Auxillary Contacts

AC-3 AC-1 230V

400V/

415V 500V 690V

1-Phase 3-Phase

115V 230V 200V 230V 460V 575V N.O. N.C. N.O. N.C.

9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2

4 0 0 4 100S-C09404BC

3 1 0 4 100S-C09304BC

12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10

4 0 0 4 100S-C12404BC

3 1 0 4 100S-C12304BC

16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15

4 0 0 4 100S-C16404BC

3 1 0 4 100S-C16304BC

23 32 7.5 11 13 10 2 3 5 7-1/2 15 15

4 0 0 4 100S-C23404BC

3 1 0 4 100S-C23304BC

For other contact configurations, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

Three-phase ratings only apply to contactors with at least three N.O. power poles.

‡ If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-

C09404BC becomes Cat. No. 100S-C09404C.

www.ab.com/catalogs     Preferred availability cat. nos. are bold.

Publication A117-CA001A-EN-P

 

\

Reversing AC- and DC-Operated Contactors

3 Main Contacts

Includes Mechanical/Electrical Interlock

Includes Reversing Power Wiring

Ie [A]

Ratings for Switching AC Motors

Aux. Contacts

Installed per

Contactor

Cat. No.

AC-2, AC-3, AC-4

3-Phase kW (50 Hz) Hp (60 Hz)

AC-3 AC-1 230V

400V/

415V 500V 690V

1-Phase 3-Phase

115V 230V 200V 230V 460V 575V N.O. N.C. ‡

9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2

0 6 104S-C09012BC

1 5 104S-C09210BC

12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10

0 6 104S-C12012BC

1 5 104S-C12210BC

16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15

0 6 104S-C16012BC

1 5 104S-C16210BC

23 32 7.5 11 13 10 2 3 5 7-1/2 15 15

0 6 104S-C23012BC

1 5 104S-C23210BC

30 65 10 15 15 15 2 5 7-1/2 10 20 25

0 5 104S-C30010BC

1 5 104S-C30210BC

37 65 11 18.5/20 20 18.5 3 5 10 10 25 30

0 5 104S-C37010BC

1 5 104S-C37210BC

43 85 13 22 25 22 3 7-1/2 10 15 30 30

0 5 104S-C43010BC

1 5 104S-C43210BC

60 100 18.5 32 37 32 5 10 15 20 40 50

0 5 § 104S-C60010BC

1 5 § 104S-C60210BC

72 100 22 40 45 40 5 15 20 25 50 60

0 5 § 104S-C72010BC

1 5 § 104S-C72210BC

85 100 25 45 55 45 7-1/2 15 25 30 60 60

0 5 § 104S-C85010BC

1 5 § 104S-C85210BC

97 130 30 55 55 55 10 15 30 30 75 75

0 5 § 104S-C97010BC

1 5 § 104S-C97210BC

For other contact configurations, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 104S-

C0905BC becomes Cat. No. 104S-C0905C.

‡ One of the N.C. auxiliary contacts is supplied as part of the mechanical/electrical interlock.

§ Bifurcated front-mount auxiliary contacts on Cat. Nos. 104S-C60…C97 conform to mirror contact performance only.

13

12

11

10

9

8

7

6

5

4

3

2

1

0

2-136

Bulletin 100S-C/104S-C

IEC Safety Contactors

www.ab.com/catalogs     Preferred availability cat. nos. are bold.

Publication A117-CA001A-EN-P

Product Selection

 

\

Coil Terminal Position

All contactors are delivered with the coil terminals located on the line side.

For load side coil terminations, insert a “U” prior to the coil voltage code.

Example: Cat. No. 100S-C09UD05BC.

Assignment of Contacts

Safety Contactors with 3 Main Contacts and Standard Front-Mount Auxiliary Contacts

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Product Selection/Assignment of Contacts

2-137

Bulletin 100S-C/104S-C

IEC Safety Contactors

K1

A2

A1

K1

A2

A1

K1

A2

A1

82

81

52

51

62

61

72

71

22

21

2

1

4

3

6

5

100S-C09 05C…C23 05C

82

81

52

51

62

61

72

71

2

1

4

3

6

5

14

13

42

41

12

11

22

21

32

31

2

1

4

3

6

5

2

1

4

3

6

5

22

21

32

31

14

13

44

43

22

21

62

61

72

71

2

1

4

3

6

5

54

53

84

83

SKU: ddf6e1d952da Category:

Description

Description

View Cut Sheet PDF

 

\

Mechanically linked N.C. auxiliary contacts

Front-mounted auxiliary contacts

− Gold bifurcated

− Permanently fixed

− Protective cover to prevent manual operation

− Red contact housing foreasy identification

− Incorporates IEC 60947-5-1 “Mechanically Linked” symbol

AC and DC operating coils

SUVA Third-Party certification

Bulletin 100S-C/104S-C safety contactors provide mechanically linked

positively guided contacts, required in feedback circuits of modern

safety applications. The mechanically linked N.C. auxiliary contacts will

not change state when a power pole welds. In addition, the gold-plated

bifurcated auxiliary contacts are ideally suited for low-energy

applications or feedback control circuits with multiple series-connected

N.C. auxiliary contacts.

Your order must include: cat. no. of the contactor specified with coil

voltage code and, if required, cat. no. of any accessories and/or

replacement coils.

Standards Compliance

Certifications

SUVA Third-Party Certified

CE Marked

cULus Listed (File No. E3125;

Guide NLDX, NLDX7)

Product Selection

3-Pole AC- and DC-Operated Contactors

Coil voltage code and terminal positionsee page 2-137

Table of Contents

Product Selection …… this page

Accessories……………… 2-142

Approximate

Dimensions………………. 2-195

Bulletin 100S-C/104S-C — IEC Safety Contactors

Cat. No.

100S-C0905C

Line Side

Cat. No.

100S-C09U05C

Load Side

Overview/Product Selection

13

12

11

10

9

8

7

6

5

4

3

2

1

0

2-134

Bulletin 100S-C/104S-C

IEC Safety Contactors

Ie [A]

Ratings for Switching AC Motors — AC-2, AC-3, AC-4 Aux. Contacts

Cat. No.

3-Phase kW (50 Hz) Hp (60 Hz)

AC-3 AC-1 230V

400V/

415V 500V 690V

1-Phase 3-Phase

115V 230V 200V 230V 460V 575V N.O. N.C.

9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2

0 5 100S-C0905BC

1 4 100S-C0914BC

12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10

0 5 100S-C1205BC

1 4 100S-C1214BC

16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15

0 5 100S-C1605BC

1 4 100S-C1614BC

23 32 7.5 11 13 10 2 3 5 7-1/2 15 15

0 5 100S-C2305BC

1 4 100S-C2314BC

30 65 10 15 15 15 2 5 7-1/2 10 20 25

0 4 100S-C3004BC

1 4 100S-C3014BC

37 65 11 18.5/20 20 18.5 3 5 10 10 25 30

0 4 100S-C3704BC

1 4 100S-C3714BC

43 85 13 22 25 22 3 7-1/2 10 15 30 30

0 4 100S-C4304BC

1 4 100S-C4314BC

60 100 18.5 32 37 32 5 10 15 20 40 50

0 4 ‡ 100S-C6004BC

1 4 ‡ 100S-C6014BC

72 100 22 40 45 40 5 15 20 25 50 60

0 4 ‡ 100S-C7204BC

1 4 ‡ 100S-C7214BC

85 100 25 45 55 45 7-1/2 15 25 30 60 60

0 4 ‡ 100S-C8504BC

1 4 ‡ 100S-C8514BC

97 130 30 55 55 55 10 15 30 30 75 75

0 4 ‡ 100S-C9704BC

1 4 ‡ 100S-C9714BC

For other contact configurations and full product details, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-

C0905BC becomes Cat. No. 100S-C0905C.

‡ Bifurcated front-mount auxiliary contacts on Cat. Nos. 100S-C60…C97 conform to mirror contact performance only.

www.ab.com/catalogs     Preferred availability cat. nos. are bold.

Publication A117-CA001A-EN-P

EN50205

CSA C22.2 No. 14

UL 508

EN/IEC 60947-4

IEC 60947-4-1 Annex H — Mirror

Contacts

IEC 60947-5-1 Annex L —

Mechanically Linked Contacts

Meets the material restrictions for

European Directive

2002/95/IEC-EU-RoHS

 

\

4-Pole AC- and DC-Operated Contactors

Coil voltage code and terminal positionsee page 2-137

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Product Selection

2-135

Bulletin 100S-C/104S-C

IEC Safety Contactors

Ie [A]

Ratings for Switching AC Motors

Contact Configuration

Cat. No. ‡

AC-2, AC-3, AC-4

Hp (60 Hz)3-Phase kW (50 Hz) Main Pole Auxillary Contacts

AC-3 AC-1 230V

400V/

415V 500V 690V

1-Phase 3-Phase

115V 230V 200V 230V 460V 575V N.O. N.C. N.O. N.C.

9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2

4 0 0 4 100S-C09404BC

3 1 0 4 100S-C09304BC

12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10

4 0 0 4 100S-C12404BC

3 1 0 4 100S-C12304BC

16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15

4 0 0 4 100S-C16404BC

3 1 0 4 100S-C16304BC

23 32 7.5 11 13 10 2 3 5 7-1/2 15 15

4 0 0 4 100S-C23404BC

3 1 0 4 100S-C23304BC

For other contact configurations, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

Three-phase ratings only apply to contactors with at least three N.O. power poles.

‡ If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-

C09404BC becomes Cat. No. 100S-C09404C.

www.ab.com/catalogs     Preferred availability cat. nos. are bold.

Publication A117-CA001A-EN-P

 

\

Reversing AC- and DC-Operated Contactors

3 Main Contacts

Includes Mechanical/Electrical Interlock

Includes Reversing Power Wiring

Ie [A]

Ratings for Switching AC Motors

Aux. Contacts

Installed per

Contactor

Cat. No.

AC-2, AC-3, AC-4

3-Phase kW (50 Hz) Hp (60 Hz)

AC-3 AC-1 230V

400V/

415V 500V 690V

1-Phase 3-Phase

115V 230V 200V 230V 460V 575V N.O. N.C. ‡

9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2

0 6 104S-C09012BC

1 5 104S-C09210BC

12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10

0 6 104S-C12012BC

1 5 104S-C12210BC

16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15

0 6 104S-C16012BC

1 5 104S-C16210BC

23 32 7.5 11 13 10 2 3 5 7-1/2 15 15

0 6 104S-C23012BC

1 5 104S-C23210BC

30 65 10 15 15 15 2 5 7-1/2 10 20 25

0 5 104S-C30010BC

1 5 104S-C30210BC

37 65 11 18.5/20 20 18.5 3 5 10 10 25 30

0 5 104S-C37010BC

1 5 104S-C37210BC

43 85 13 22 25 22 3 7-1/2 10 15 30 30

0 5 104S-C43010BC

1 5 104S-C43210BC

60 100 18.5 32 37 32 5 10 15 20 40 50

0 5 § 104S-C60010BC

1 5 § 104S-C60210BC

72 100 22 40 45 40 5 15 20 25 50 60

0 5 § 104S-C72010BC

1 5 § 104S-C72210BC

85 100 25 45 55 45 7-1/2 15 25 30 60 60

0 5 § 104S-C85010BC

1 5 § 104S-C85210BC

97 130 30 55 55 55 10 15 30 30 75 75

0 5 § 104S-C97010BC

1 5 § 104S-C97210BC

For other contact configurations, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 104S-

C0905BC becomes Cat. No. 104S-C0905C.

‡ One of the N.C. auxiliary contacts is supplied as part of the mechanical/electrical interlock.

§ Bifurcated front-mount auxiliary contacts on Cat. Nos. 104S-C60…C97 conform to mirror contact performance only.

13

12

11

10

9

8

7

6

5

4

3

2

1

0

2-136

Bulletin 100S-C/104S-C

IEC Safety Contactors

www.ab.com/catalogs     Preferred availability cat. nos. are bold.

Publication A117-CA001A-EN-P

Product Selection

 

\

Coil Terminal Position

All contactors are delivered with the coil terminals located on the line side.

For load side coil terminations, insert a “U” prior to the coil voltage code.

Example: Cat. No. 100S-C09UD05BC.

Assignment of Contacts

Safety Contactors with 3 Main Contacts and Standard Front-Mount Auxiliary Contacts

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Product Selection/Assignment of Contacts

2-137

Bulletin 100S-C/104S-C

IEC Safety Contactors

K1

A2

A1

K1

A2

A1

K1

A2

A1

82

81

52

51

62

61

72

71

22

21

2

1

4

3

6

5

100S-C09 05C…C23 05C

82

81

52

51

62

61

72

71

2

1

4

3

6

5

14

13

42

41

12

11

22

21

32

31

2

1

4

3

6

5

2

1

4

3

6

5

22

21

32

31

14

13

44

43

22

21

62

61

72

71

2

1

4

3

6

5

54

53

84

83

Related products